Ir arriba
Información del artículo en conferencia

Vibration monitoring of electric generators without sensor dedicated

P. Vieira Junior, M.A. Sanz-Bobi, C. Ruiz Gomes, H. Simões Gomes, M. Pacheco do Nascimento

International Conference on Industrial Technology - ICIT 2010, Viña del Mar (Chile). 14-17 marzo 2010


Resumen:

This paper describes a method for on-line condition monitoring of rotating electric generators without a need for installed sensors dedicated. This sensorless method has been based on continuous monitoring vibration using neural networks for the classification of bearing failures experimentally induced. The results obtained have an error of less than 0,5% confirming the validity of the method proposed.


DOI: DOI icon https://doi.org/10.1109/ICIT.2010.5472760

Publicado en: ICIT 2010: Conference proceedings, pp: 451-456, ISBN: 978-1-4244-5695-6

Fecha de publicación: 27-may-2010


Cita:
P. Vieira Junior, M.A. Sanz-Bobi, C. Ruiz Gomes, H. Simões Gomes, M. Pacheco do Nascimento, "Vibration monitoring of electric generators without sensor dedicated", presentado en International Conference on Industrial Technology - ICIT 2010, Viña del Mar, Chile, 14-17 marzo 2010. En: ICIT 2010: Conference proceedings, pp. 451-456, doi: 10.1109/ICIT.2010.5472760

    Líneas de investigación:
  • *Inteligencia artificial aplicada al mantenimiento, diagnostico y fiabilidad
    Grupos de investigación:
  • Instituto de Investigación Tecnológica (IIT)

IIT-10-002A

pdf Solicitar el artículo completo a los autores